Curaflex® C/S

  • Sealing of penetrations
  • Use in lining pipe provided by the customer or WU concrete core drilling (white tank)
  • if too large or too small unusual opening sizes
  • with special dimensions

Technical details

  • Tested in accordance with FHRK test specification GE 101 (No. G 30 322-2-2) - FHRK 57 LD10
  • Gas and water-tight
  • Radon-tight - in accordance with FHRK data sheet MB 101, meets the requirements for radon precaution areas
  • Angles of the service pipes up to 8º possible
  • Absorption of axial movements
  • Double-sealing

Areas of use

  • Sealing of penetrations
  • Use in lining pipe provided by the customer or WU concrete core drilling (white tank)
  • if too large or too small unusual opening sizes
  • with special dimensions

Product benefits

  • Permanently tight without retensioning (maintenance-free)
  • Higher sealing performance of the seal insert thanks to DOYMA-Grip
  • System component, without cuts or divisions, with watertight welded bolts
  • Manufactured to specification

  • Frame rings: Steel rings, ggv corrosion protection coating; optionally made of stainless steel 1.4301 (V2A) or 1.4571/1.4404 (V4A)
  • Rubber seal: Elastomer, 2 x 27 mm thick EPDM seals (DOYMA-Grip), optionally EPDM-TW, NBR (fuel/oil resistant) or silicone (high temperature resistant) or FPM (chemical resistant)
  • Orange center ring (up to KB/DN 350)

Media